On this page
01 The bugTraq.html page and why it was linked
Foundry published its security notices on a single page at the root of the corporate site, named bugTraq.html after the disclosure mailing list of the era. The page listed each advisory with the affected products, the IronWare releases that fixed it and sometimes a link to a longer response document. Vulnerability databases and mailing-list archives linked to it as the vendor statement, which made it one of the most externally linked URLs on the domain. After the Brocade integration the page disappeared and those citations broke. This page records what was there in general terms and does not reproduce the notices.
02 February 2002: multi-vendor SNMP vulnerabilities (CA-2002-03)
In February 2002 the CERT Coordination Center published advisory CA-2002-03 after the Oulu University Secure Programming Group (OUSPG) released its PROTOS test suite of malformed SNMPv1 messages. Nearly every network vendor was affected, and operators assumed Foundry was too because IronWare shipped an SNMP agent listening by default. The CERT/CC vulnerability notes (VU#854306 and VU#107186) record Foundry's status as Not Affected: its vendor statement, updated 18 February 2002, said PROTOS testing found no Foundry device affected on SNMP v1, v2c or v3. The sensible advice at the time still applied, filter UDP 161 and 162 at the network edge and keep agents patched. The SNMP MIBs page covers the protocol side.
03 September 2003: OpenSSH buffer management (CA-2003-24)
CERT advisory CA-2003-24 of September 2003 described a buffer management error in OpenSSH releases before 3.7. Embedded devices whose SSH servers derived from that code were exposed, and Foundry published a notice for the IronWare SSH implementation under /solutions/advisories/. The fix was an IronWare update; the interim mitigation was an access list limiting which hosts could open TCP 22 to the device.
04 April 2004: TCP reset attacks (NISCC 236929)
In April 2004 the UK NISCC published advisory 236929. It showed that a spoofed TCP RST or SYN segment only needed a sequence number inside the receive window, not an exact match, to tear down a connection, and that long-lived BGP sessions between routers were the natural target. Foundry, whose NetIron routers ran BGP in service provider cores, published a TCP vulnerability response document listing affected releases and mitigations: TCP MD5 signatures on BGP sessions (RFC 2385) and ingress filtering of spoofed sources.
05 Other advisory classes of the era
- Default SNMP community strings. Early IronWare shipped with the read-only community
publicand, on some releases, a read-write community, giving configuration access to anyone on the management network. - Telnet exposure. Telnet was on by default and carried credentials in clear text; several notices concerned telnet authentication behaviour on specific releases.
- Web management interface. The HTTP interface had authentication and input handling bugs common to every vendor of the period.
| Era | Class | Fix then | Mitigation now |
|---|---|---|---|
| 2002 | SNMPv1 malformed message handling (CA-2002-03) | IronWare update; filter UDP 161 and 162 | SNMPv3 or disable SNMP; ACL to manager hosts |
| 2003 | SSH server buffer management (CA-2003-24) | IronWare update | Restrict TCP 22 by ACL; SSH version 2 only |
| 2004 | TCP reset in window (NISCC 236929) | TCP MD5 on BGP; ingress filtering | Same; no BGP to untrusted peers on a legacy box |
| 2000s | Default communities, telnet, HTTP management | Configuration change | Disable telnet and HTTP; change communities; management VLAN |
06 Hardening a legacy IronWare device today
No vendor issues fixes for Foundry-era IronWare. The only controls left are exposure and configuration. The list below is the minimum.
- Put the management IP on a dedicated management VLAN (VLANs) not routed to the internet or to user segments.
- Disable telnet and the HTTP management interface. Use SSH version 2 only and regenerate the host key so a previous owner does not hold it.
- Disable SNMP unless polling is needed. If it is, use SNMPv3 where the release supports it, otherwise a long random read-only community restricted by ACL. Never enable a read-write community.
- Apply access lists to every management service so only the monitoring host and the admin jump host can reach the device.
- Change every password, remove unknown user accounts, and do not expose any service to the internet.
configure terminal no telnet server no web-management http crypto key generate rsa access-list 10 permit host 10.10.0.5 ssh access-group 10 no snmp-server community public ro snmp-server community LONG-RANDOM-STRING ro 10 enable super-user-password NEW-PASSWORD write memory
Exact keywords vary between IronWare releases and between switch and router images; see the CLI reference. Verify from outside with a port scan of the management address: only TCP 22, and UDP 161 if SNMP is required, should answer. Unknown credentials are handled under password recovery. The exposure is worse for the security and wireless products: the inspection code on SecureIron firewall load balancers and the firmware on IronPoint access points have had no fixes since the late 2000s. Every affected family is listed from the Foundry product archive.
A second-hand IronWare device with telnet, HTTP and the public community on a routable address is a 2002-era attack surface. Treat the checklist as mandatory.
07 Foundry Networks security advisories: reading the record today
The durable copies of these advisories are the CERT/CC vulnerability notes, each with a vendor section giving a dated status and, where supplied, a statement. Read the statement, not the list. On VU#107186 and VU#854306, the two notes behind CA-2002-03, Foundry is listed as Not Affected, updated February 18, 2002, with a statement that testing with the PROTOS tools found no Foundry device affected on SNMP v1, v2c or v3. On VU#333628, the OpenSSH note of September 16, 2003, Foundry is listed as Affected with no statement and an addendum pointing to /solutions/advisories/openssh333628.html on this domain. On VU#415294, the April 2004 TCP reset note, Foundry does not appear at all; its response was the standalone document under /solutions/security/.
| Advisory | CERT/CC note and CVE | Foundry status on the note | What to check |
|---|---|---|---|
| SNMPv1 request handling, Feb 2002 | VU#854306, CVE-2002-0013 | Not Affected, statement of Feb 2002 | The statement text and its update date |
| SNMPv1 trap handling, Feb 2002 | VU#107186, CVE-2002-0012 | Not Affected, same statement | As above |
| OpenSSH buffer management, Sep 2003 | VU#333628, CVE-2003-0693 | Affected; addendum links the Foundry page | The archived openssh333628.html capture |
| TCP reset in window, Apr 2004 | VU#415294, CVE-2004-0230 | Not listed | The archived PDF under /solutions/security/ |
The bugTraq page survives only as web archive captures, which do not show when each notice was added. To verify a claim about a Foundry vulnerability: find the VU number, read the vendor status and its date, then find a capture of the matching Foundry page and note the capture date, following archiving the advisory pages themselves. A fixed IronWare release or a CVE that appears in no note and no capture should be treated as invented; the provenance section applies the same test of origin and date to content in transit.
Because no fix is coming, the record of who reached the management plane is the control that remains. Send syslog to a collector kept under the rules for logging that stands up as evidence, so a login from an unexpected host is provable, not merely noticed.
08 Questions
Where did Foundry publish security advisories?
On a page named bugTraq.html at the root of www.foundrynet.com, with longer response documents under /solutions/advisories/ and /solutions/security/. The page was retired after Brocade absorbed the site; web archive captures are the only surviving copies.
Did Foundry devices have the 2002 SNMP vulnerability?
According to the CERT/CC record, no. CA-2002-03 covered malformed SNMPv1 message handling found by the OUSPG PROTOS suite, and the vulnerability notes list Foundry as Not Affected, with a vendor statement that PROTOS testing found no Foundry device affected on SNMP v1, v2c or v3. Filtering SNMP ports at the edge was still the standard precaution.
What was the 2004 TCP reset advisory about?
NISCC 236929 showed that a spoofed reset needed only a sequence number inside the receive window, making long-lived BGP sessions practical to tear down. Foundry published a TCP vulnerability response recommending TCP MD5 authentication on BGP sessions and ingress filtering.
Can I still get security patches for IronWare?
No. Foundry ceased to exist as a company in 2008 and the successor vendors do not issue fixes for Foundry-era hardware. The remaining controls are configuration and exposure: disable clear-text services, restrict management by ACL and isolate the management VLAN.
Is SNMPv3 available on old IronWare?
On later IronWare releases, yes, with authentication and privacy. Early releases support only SNMPv1 and v2c. If your release lacks SNMPv3, use a long random read-only community bound to an access list, or disable SNMP and rely on syslog and sFlow.
What did Foundry say about the 2002 SNMP vulnerability?
The CERT/CC notes VU#107186 and VU#854306 record Foundry's status as Not Affected, updated February 18, 2002, with a vendor statement that testing using the PROTOS tools found no Foundry device affected on SNMP v1, v2c or v3. Filtering SNMP at the edge was still sensible practice for every vendor's gear at the time.